-40%
LIGHTLY USED : Brocade MLXe-8 Router Chassis + Cards
$ 2006.4
- Description
- Size Guide
Description
Used in a lab - never deployed in the field. See below:Brief Info:
***
MLX
e 8-slot Chassis
1 BR-
MLX
-MR2-X Management Module
2 NI-X-HSF Switch Fabric Module
1 BR-
MLX
-10Gx8-X 8-port 10GbE (X) Module
1 BR-
MLX
-1GCx24-X 24-port 10/100/1000Base-T Copper Module
1 BR-
MLX
-1GFx24-X 24-port 1GbE SFP Module
2 1800W PSUs
NetIron XMR-8000 Router#
NetIron XMR-8000 Router#
NetIron XMR-8000 Router#show module
Module Status Ports Starting MAC
M1 (left ):BR-
MLX
-MR2-X Management Module Active
M2 (right):
F1: NI-X-HSF Switch Fabric Module Active
F2: NI-X-HSF Switch Fabric Module Active
F3:
S1: BR-
MLX
-10Gx8-X 8-port 10GbE (X) Module CARD_STATE_UP 8 cc4e.249a.0e00
S2: BR-
MLX
-1GCx24-X 24-port 10/100/1000Base-T Copper Module CARD_STATE_UP 24 cc4e.249a.0e30
S3: BR-
MLX
-1GFx24-X 24-port 1GbE SFP Module CARD_STATE_UP 24 cc4e.249a.0e60
S4:
S5:
S6:
S7:
S8:
NetIron XMR-8000 Router#show chas
chassis Power supply/fan/temperature
NetIron XMR-8000 Router#show chassis
***
MLX
e 8-slot Chassis ***
---POWERS ---
Power 1: (23-0000129-03 BMG2M25LGE2 - AC 1800W): Installed (OK)
Power 2: Installed (Failed or Disconnected)
Power 3: not present
Power 4: not present
Total power budget for chassis = 1800 W
Total power used by system core = 832 W
Total power used by LPs = 590 W
Total power available = 378 W
Slot Power-On Priority and Power Usage:
Slot1 pri=1 module type=BR-
MLX
-10Gx8-X 8-port 10GbE (X) Module power usage=270W
Slot2 pri=1 module type=BR-
MLX
-1GCx24-X 24-port 10/100/1000Base-T Copper Module power usage=160W
Slot3 pri=1 module type=BR-
MLX
-1GFx24-X 24-port 1GbE SFP Module power usage=160W
--- FANS ---
Back fan A-1: Status = OK, Speed = LOW (50%)
Back fan A-2: Status = OK, Speed = LOW (50%)
Back fan B-1: Status = OK, Speed = LOW (50%)
Back fan B-2: Status = OK, Speed = LOW (50%)
--- TEMPERATURE READINGS ---
Active Mgmt Module: 37.750C 52.125C
SFM1: FE1:33.250C FE2:33.250C FE3:33.250C
SFM2: FE1:33.625C FE2:33.625C FE3:33.625C
SFM3: not present
LP1 Sensor1: 44.375C
LP1 Sensor2: 45.125C
LP1 Sensor3: UNUSED
LP1 Sensor4: 36.625C
LP1 Sensor5: 43.500C
LP1 Sensor6: UNUSED
LP1 Sensor7: UNUSED
LP2 Sensor1: 54.0C
LP2 Sensor2: 53.125C
LP2 Sensor3: UNUSED
LP3 Sensor1: 39.0C
LP3 Sensor2: 38.0C
LP3 Sensor3: UNUSED
Fans are in auto mode (current speed is LOW (50%)). Temperature monitoring poll period is 60 seconds.
--- MISC INFO ---
Backplane EEPROM MAC Address: cc4e.249a.0e00
NetIron XMR-8000 Router#
NetIron XMR-8000 Router#show version
System Mode: XMR
Chassis:
MLX
e 8-slot (Serial #: BGB2551L009, Part #: 40-1000362-04)
NI-X-HSF Switch Fabric Module 1 (Serial #: BEU3247L01B, Part #: 60-1003267-01)
FE 1: Type fe600, Version 1
FE 3: Type fe600, Version 1
Switch Fabric Module 1 Up Time is 28 minutes 25 seconds
NI-X-HSF Switch Fabric Module 2 (Serial #: BEU3247L01C, Part #: 60-1003267-01)
FE 1: Type fe600, Version 1
FE 3: Type fe600, Version 1
Switch Fabric Module 2 Up Time is 28 minutes 25 seconds
==========================================================================
SL M1: BR-
MLX
-MR2-X Management Module Active (Serial #: BVR2551L019, Part #: 60-1003269-01):
Boot : Version 5.6.0T165 Copyright (c) 1996-2013 Brocade Communications Systems, Inc.
Compiled on Sep 20 2013 at 16:42:38 labeled as xmprm05600
(516258 bytes) from boot flash
Monitor : Version 5.6.0T165 Copyright (c) 1996-2013 Brocade Communications Systems, Inc.
Compiled on Sep 20 2013 at 16:41:56 labeled as xmb05600
(534157 bytes) from code flash
IronWare : Version 5.6.0gT163 Copyright (c) 1996-2013 Brocade Communications Systems, Inc.
Compiled on Aug 27 2015 at 23:23:54 labeled as xmr05600g
(9462533 bytes) from Primary
Board ID : 00 MBRIDGE Revision : 37
1666 MHz Power PC processor 7448 (version 8004/0202) 166 MHz bus
512 KB Boot Flash (MX29LV040C), 128 MB Code Flash (MT28F256J3)
4096 MB DRAM INSTALLED
4096 MB DRAM ADDRESSABLE
Active Management uptime is 28 minutes 25 seconds
==========================================================================
SL 1: BR-
MLX
-10Gx8-X 8-port 10GbE (X) Module (Serial #: BQQ0428L010, Part #: 60-1002031-10)
(LID: dssFJHNnFGF)
Boot : Version 5.6.0T175 Copyright (c) 1996-2013 Brocade Communications Systems, Inc.
Compiled on Sep 20 2013 at 16:43:00 labeled as xmlprm05600
(423373 bytes) from boot flash
Monitor : Version 5.6.0T175 Copyright (c) 1996-2013 Brocade Communications Systems, Inc.
Compiled on Sep 20 2013 at 16:43:26 labeled as xmlb05600
(539767 bytes) from code flash
IronWare : Version 5.6.0gT177 Copyright (c) 1996-2013 Brocade Communications Systems, Inc.
Compiled on Aug 27 2015 at 23:30:30 labeled as xmlp05600g
(7503085 bytes) from Primary
FPGA versions:
Valid PBIF Version = 2.16, Build Time = 6/10/2014 11:47:00
Valid XPP Version = 7.04, Build Time = 8/26/2013 9:57:00
X10G2MAC 0
X10G2MAC 1
X10G2MAC 2
X10G2MAC 3
1333 MHz MPC 8541 (version 8021/0022) 533 MHz bus
512 KB Boot Flash (MX29LV040C), 64 MB Code Flash (MT28F256J3)
2048 MB DRAM, 8 KB SRAM, 286331153 Bytes BRAM
LP Slot 1 uptime is 27 minutes 41 seconds
==========================================================================
SL 2: BR-
MLX
-1GCx24-X 24-port 10/100/1000Base-T Copper Module (Serial #: BNA0442L00P, Part #: 60-1001878-11)
License:
MLX
-1Gx24-X-Upgrade (LID: dpcFJJHnFFr)
Boot : Version 5.6.0T175 Copyright (c) 1996-2013 Brocade Communications Systems, Inc.
Compiled on Sep 20 2013 at 16:43:00 labeled as xmlprm05600
(423373 bytes) from boot flash
Monitor : Version 5.6.0T175 Copyright (c) 1996-2013 Brocade Communications Systems, Inc.
Compiled on Sep 20 2013 at 16:43:26 labeled as xmlb05600
(539767 bytes) from code flash
IronWare : Version 5.6.0gT177 Copyright (c) 1996-2013 Brocade Communications Systems, Inc.
Compiled on Aug 27 2015 at 23:30:30 labeled as xmlp05600g
(7503085 bytes) from Primary
FPGA versions:
Valid PBIF Version = 4.02, Build Time = 8/26/2013 14:27:00
Valid XPP Version = 1.01, Build Time = 9/6/2013 14:18:00
Valid STATS Version = 0.09, Build Time = 11/21/2010 14:52:00
BCM56512GMAC 0
BCM56512GMAC 1
666 MHz MPC 8541 (version 8020/0020) 333 MHz bus
512 KB Boot Flash (MX29LV040C), 16 MB Code Flash (MT28F128J3)
1024 MB DRAM, 8 KB SRAM, 286331153 Bytes BRAM
LP Slot 2 uptime is 7 minutes 5 seconds
==========================================================================
SL 3: BR-
MLX
-1GFx24-X 24-port 1GbE SFP Module (Serial #: BND0447L002, Part #: 60-1001892-12)
License:
MLX
-1Gx24-X-Upgrade (LID: dpfFJJMnFFH)
Boot : Version 5.6.0T175 Copyright (c) 1996-2013 Brocade Communications Systems, Inc.
Compiled on Sep 20 2013 at 16:43:00 labeled as xmlprm05600
(423373 bytes) from boot flash
Monitor : Version 5.6.0T175 Copyright (c) 1996-2013 Brocade Communications Systems, Inc.
Compiled on Sep 20 2013 at 16:43:26 labeled as xmlb05600
(539767 bytes) from code flash
IronWare : Version 5.6.0gT177 Copyright (c) 1996-2013 Brocade Communications Systems, Inc.
Compiled on Aug 27 2015 at 23:30:30 labeled as xmlp05600g
(7503085 bytes) from Primary
FPGA versions:
Valid PBIF Version = 4.02, Build Time = 8/26/2013 14:27:00
Valid XPP Version = 1.01, Build Time = 9/6/2013 14:18:00
Valid STATS Version = 0.09, Build Time = 11/21/2010 14:52:00
BCM56512GMAC 0
BCM56512GMAC 1
666 MHz MPC 8541 (version 8020/0020) 333 MHz bus
512 KB Boot Flash (MX29LV040C), 16 MB Code Flash (MT28F128J3)
1024 MB DRAM, 8 KB SRAM, 286331153 Bytes BRAM
LP Slot 3 uptime is 7 minutes 4 seconds
==========================================================================
All show version done